Next: Determination of Drift Velocity
Up: Drift Chamber (DC) Calibration
Previous: Drift Chamber (DC) Calibration
  Contents
When charged particles ionize the drift chamber gas,
the resulting drift electrons travel to the anode wire (sense wire).
The drift distance (
) the electron in the ionized gas must travel
within the drift chamber to reach the sense wire is given by (26),
 |
(5.1) |
where
is velocity of the drift electron,
is the time as
measured in the TDC's, and
is the time corresponding to
,
i.e. the time in the absence of any drift,
referred to as the time pedestal.
The time pedestal for each wire was defined as
the time corresponding to the half
maxima at the leading edge of the TDC drift time
spectra (Figure 5.1).
Figure 5.1:
The drift time spectra for a sense wire in Super layer 1.
As seen above, time pedestal
is 50.63 FBTDC channels = 101.26 ns.
 |
The mean fit residual for particles passing on the right side of the sense
wire (
) and for particles passing on the left (
) is calculated using
the set of time pedestal values (
). A correction for the time
pedestal
is obtained from,
 |
(5.2) |
Applying these corrections to the 1632 time pedestals, a
new set of 1632 pedestals are obtained, and the process is repeated until
the correction
t is found to be negligibly small.
After ten iterations,
t was found to be
vanishingly small, indicating convergence of the iteration
procedure. A similar
procedure was applied to the position of the sense wires, the
wire position corrections however, were found to be negligible.